Page 182 - Catalog Book V1V2
P. 182

5. Operation and Maintenance of the Re-Circulating Cooling System
           pH range:
           Evaporative media provides optimal long life if the pH of the re-circulating water is between 6 and 9,
           which is normal for most water. If re-circulating water pH is outside this range, consult an AP/Cumberland
           sales technician.
          AP Re-Circulating Closed Top
          Cooling System (RCS-10)                                                                                      VENTILATION
           Re-Circulating Closed Top Cooling System (RCS-10)

































                                                        Figure 5A
           Ref #    APS Part #     Vendor Part #            Description
             1      V-1914         60-0269                  Trough End with Nipple Cap
                                Ref #     Part #                  Description
             2      V-2176        1  60-0299         Trough End with Nipple Cap
                                                            Evap trough, 10' Long, 6" x 9"
                                       60-0269
                                                            Trough Coupler
             3      V-1437        2  60-0267         Evap Trough, 10' Long, 6" x 9"
                                       60-0299
                                       60-0267
             4      V-2180        3  60-0295         Trough Coupler
                                                            10' Top Back Cover, Closed Top
                                       60-0295
             5      V-2027        4  60-0270A        10' Top Back Cover, Closed Top
                                                            Spray Bar Support Bracket Assembly
                                  5    60-0270A      Spray Bar Support Bracket Assembly
             6      V-2104         60-0353                  10' Spray Bar, 1-1/2" PVC
                                  6    60-0353       10' Spray Bar, 1-1/2" PVC
             7      V-1913         60-0268                  Trough End Cap
                                  7    60-0268       Trough End Cap
             8      V-2181         60-0301                  Evap Trough Cover, 10' Long
                                  8    60-0301       Evap Trough Cover, 10' Long
             9      V-2182         60-0080                  Supply Line
                                  9    60-0080       Supply Line
                                                            End Panel
             10     NA           10 NA  N/A          End Panel
                                                            10' Top Front Cover, Closed Top
             11     V-2015       11 60-0297          10' Top Front Cover, Closed Top
                                       60-0297
           NOTE: Some parts can be ordered in 5' or 10' lengths.

           End panels are ordered according to system height.



           PNEG-885 Evaporative Cooling System                                                                   41







 180  CALL FOR SPECIFICATIONS AND PRICING               AGPROPERTYSOLUTIONS.COM   |   855.345.6333               181
   177   178   179   180   181   182   183   184   185   186   187